CURIOTEC PRECISION LOAD CELLS

CURIOTEC Truck Scale Load Cells

CURIOTEC CDSB-B, RPWB, NDSB-B & Digital Load Cells CDSB-30BYD, RPWB-30TYD, CDSB-D — High-reliability noise immunity and smart diagnostic weighing solutions.

Truck Scale Std / Nickel Steel
CURIOTEC CDSB-B (Analog)
Truck Weighing Load Cell (3 tf ~ 15 tf)

CURIOTEC CDSB-B (Analog)

Nickel Plated Steel Rated Capacity : 3 tf ~ 15 tf (10, 15 tf)
CURIOTEC standard analog load cell dedicated to truck weighing (3T~15T)
Robust structural design for easy installation and high durability
Strong resistance against shock and lateral side forces
Rated output: 2.0 ± 0.004 mV/V, combined error: 0.03% RO
Online Quote Inquiry
OIML & CE / IP68 Waterproof
CURIOTEC RPWB (Analog)
Truck Weighing Load Cell (25, 30, 50 tf)

CURIOTEC RPWB (Analog)

Stainless Steel Rated Capacity : 25, 30, 50 tf
CURIOTEC RPWB Analog Load Cell dedicated to truck scales
OIML and CE internationally certified high-durability truck scale load cell
Built-in lightning surge protection and rotation-protected structure
Protection class IP68 hermetically sealed all-stainless steel body
Online Quote Inquiry
Up to 100tf / Heavy-Duty
CURIOTEC NDSB-B (Analog/Digital)
Truck Weighing Load Cell (25, 30, 50, 100 tf)

CURIOTEC NDSB-B (Analog/Digital)

Paint Finished Steel Rated Capacity : 25, 30, 50, 100 tf
Analog / Digital NDSB-25B (NDSB-B) heavy-duty load cell supporting 25tf~100tf
Rocker pin / ball design for auto-centering and side-load absorption
Paint-finished alloy steel optimized for construction and port logistics sites
High accuracy with combined error of 0.02% RO
Online Quote Inquiry
RS-485C Digital / 1,000,000 Counts
CURIOTEC CDSB-30BYD (Digital)
Digital Load Cell (10tf, 20tf, 30tf)

CURIOTEC CDSB-30BYD (Digital)

Nickel Plated Steel Rated Capacity : 30 tf (10tf, 20tf, 30tf / 1,000,000 Counts)
Identical dimensions to analog load cells for seamless 1:1 replacement
RS-485C protocol with ultra-compact (25x6mm) internal digital module
Easy maintenance, high-resolution digital data transmission for superior stability
IP68 dust/water protection (Rated output: 1,000,000 counts, RS-485 2-Wire)
Online Quote Inquiry
All Stainless / IP68 Waterproof
CURIOTEC RPWB-30TYD (Digital)
Digital Stainless Load Cell (10tf, 20tf, 30tf)

CURIOTEC RPWB-30TYD (Digital)

Stainless Steel Rated Capacity : 30 tf (10tf, 20tf, 30tf / 1,000,000 Counts)
All-stainless steel body optimized for corrosive, saline, and chemical environments
Same dimensions as analog cells for easy retrofitting of existing truck scales
Built-in miniature digital module with RS-485C serial protocol
IP68 rating with 1,000,000 count high-resolution data transmission
Online Quote Inquiry
200k Counts / Internal Diagnostics
CURIOTEC CDSB-D (Digital 10T, 15T)
Digital Load Cell (10, 15 tf)

CURIOTEC CDSB-D (Digital 10T, 15T)

Nickel Plated Steel Rated Capacity : 10 tf, 15 tf (200,000 Counts)
High resolution digital output via RS-485 (4-wire) up to 1,000m transmission
Internal diagnostics detecting errors and anomalous status in real time
United structure between sensing and mounting part for effective maintenance
Rated output: 200,000 counts, Combined error: 0.03% RO, Excitation: DC 12V
Online Quote Inquiry
LOAD CELL TECH COMPARISON

Analog vs. Digital Load Cells: Pros, Cons & Selection Guide

Optimal truck scale load cell selection criteria tailored to site environment, budget, and maintenance conditions.

1

Analog Load Cell

Standard Industrial Scale
Key Advantages (Pros)
✓ Cost-Effective

20~40% lower initial installation cost compared to digital models of the same capacity.

✓ Wide Compatibility

Directly connects to most indicators, amplifiers, and PLCs (Standard 4~6 wire Ex+, Ex-, Sig+, Sig-).

✓ Easy Repair & Replacement

Cables can be replaced/extended individually, and single faulty cells can be swapped easily.

✓ Field-Proven Reliability

Over 40 years of industrial standard operation with extensive field maintenance infrastructure.

Key Limitations (Cons)
Vulnerable to Noise : Micro-voltage (mV) signals may distort over long cables or near welding sparks and high-frequency inverters.
Manual Corner Adjustment : Requires manual potentiometer trimming across 4~6 corners during installation.
Cumulative Variance : Slight cell-to-cell tolerances in multi-cell systems can cause 5~10kg corner variance.
Sensitive to Moisture : Cable moisture ingress or jacket damage can cause weight drift or hunting.
2

Digital Load Cell

Smart Diagnostics & Noise Free
Key Advantages (Pros)
✓ Superior Noise Immunity

Internal A/D conversion with digital serial transmission ensures loss-free stability up to 1,000m.

✓ Automatic Corner Calibration

Indicator automatically balances individual corners, drastically cutting truck scale commissioning time.

✓ Smart Self-Diagnostics

Immediately displays the specific faulty load cell ID on the indicator for rapid troubleshooting.

✓ High Precision & Fault Detection

Ideal for high-noise scrap/steel yards; automatically detects cable shorts and moisture anomalies.

Key Limitations (Cons)
Higher Unit Cost : Sensor unit cost is approximately 1.5~2x higher than analog cells.
Dedicated Indicator Required : Uses manufacturer-specific digital communication protocols.
Module Replacement : Requires full unit replacement if the internal A/D module is damaged.
Connector Sealing Care : Requires proper waterproof sealing at connector joints to prevent communication errors.
3

Which One Should You Choose? (Site Selection Guide)

Recommended Sites for Analog Load Cells
  • Budget Priority : Plants and logistics sites with tight initial installation budgets
  • General Weighing : Standard industrial weighing applications with normal accuracy requirements
  • Static Scales : Coil scales, pallet scales, and standard hopper scales
  • Existing Infrastructure : Sites where maintenance teams are already familiar with analog systems
Recommended Sites for Digital Load Cells
  • Truck Scales (Weighbridges) : Highly recommended due to long cable runs, outdoor noise, and weather
  • High-Noise Plants : Factories with inverters, welding machines, and heavy motors
  • 24/7 Continuous Operations : Steel mills, asphalt/concrete plants, and port logistics centers
  • Smart Monitoring : Unmanned weighing systems requiring remote diagnostics and high precision
4

Quick Comparison Summary

Swipe horizontally
Category Analog Load Cell Digital Load Cell
Cost Economical (20~40% lower than digital) Higher (1.5~2x compared to analog)
Noise Immunity Sensitive (Micro-voltage mV signal) Very Strong (Digital communication up to 1,000m)
Installation Manual corner trimming via junction box resistors Automatic corner balancing via indicator
Maintenance Simple & low cost (Standardized parts) Manufacturer-specific protocol & module
Stability Affected by temperature, humidity & cable length High stability (Self-compensation & minimal drift)
Diagnostics Manual testing required for each cell Instant error code & cell ID check on indicator
Compatibility Universal (Standard 4~6 wire interface) Requires dedicated digital indicator
Quote Inquiry